The set up and reporting tools all reside on the unit. To use the utilities, type the IP address of the unit into your web browser.

Multiple Unit Synchronization
For multiple production lines, more than one CodeWatch Basic can be installed. The units can be configured to pass the match code set up from one leader to many followers alleviating the need to configure multiple units for every barcode change.


Screw Terminal Connector

The relay outputs can be wired using the attached screw terminals. It includes one mechanical relay and two optical isolated outputs.

Internet Ready
Ethernet capability built into every unit. Make configuration changes over your network or view reports from your desktop PC with a web browser.

In the Field Firmware Upgrades
Using a small software utility, the firmware can be upgraded in the field. New firmware enhancements and upgrades are free to registered users.


 

The standard package includes everything you need for match code operations:

 
   
  • CodeWatch Basic unit
  • One barcode scanner
  • One photo eye
  • Cable for the barcode scanner
  • Crossover Ethernet cable
  • Line cord
  • Scanner Mount
 
   

Primary Electrical Input

Input Voltage

100-240 VAC

Power Consumption

25 Watts (Max)

Input Frequency

50-60 Hz

 
   

CodeWatch Performance

Maximum Read Cycles

3000 Triggers/Minute

Output Events

600 Outputs/Minute

 

Relay Output 1

Output Type

Mechanical relay SPDT type.

Max Switching Voltage

60 Volts DC & 60 Volts AC

Maximum Switching Current

0.5 Amperes Continuous

Minimum Load

1mA @ 5 Volts DC

Optical Isolated Outputs 2 & 3

Output Type

Solid-state optical isolated NPN type.

Collector Current Max

50mA per channel continuous.

Voltage Collector-Emitter Max

80 Volts DC

Voltage C-E Saturation Max

0.3 Volts

Rise Time – 100 Ohm Load

3uS (typical)

Rise Time – 1K Ohm Load

< 20uS (typical)

Fall Time – 100 Ohm Load

5uS (typical)

Fall Time – 1K Ohm Load

< 20uS (typical)

Audio Outputs

Output Type

Mallory Sonalert

Maximum Audible Level

< 80dB

Trigger Input (DIN 6)

Input Type

Current sinking type.

Voltage Output Supply

24 Volts DC

Maximum Output Current

0.1 Amperes Maximum

Minimum Signal Voltage

4.5 Volts

Maximum Signal Voltage

24 Volts

Maximum Signal Current Draw

< 15 milliamperes @ 24 Volts DC

Minimum Debounce Timing

10mS

Minimum Valid Trigger Timing

> 15mS

   

Primary DC Electrical Outputs (WECO connector)

Voltage Output

24 Volts +/- 1.4 V

Max Current Output

0.5 Amperes Continuous

Voltage Ripple Output

200mVolts Peak to Peak

Voltage Output Fused

 

HD-15 Connector Pin Assignments

Pin

Function

1

5 Volts (0.5A Continuous Max)

2

TX (In from scanner)

3

RX (Out from scanner)

4

Power & Signal Ground

5

Trigger Output (Current-Sinking Output)

6

N.C.

7

Input 1 (Output 1 from scanner)

8

Default Output

9

24 Volts (0.5A Continuous Max)

10

24 Volts (0.5A Continuous Max)

11

Input 3 (Output 3 from scanner)

12

N.C.

13

Chassis Ground

14

Input 2 (Output 2 from scanner)

15

Power & Signal Ground

 
         